AW: [Doepfer_a100] a111( high end vco with 3340) issue

From yahoo
Sent Mon, Sep 26th 2016, 09:07

From the distance it's impossible to find out what's wrong. But the A-111
cannot be damaged by a "wrong" CV coming from the bus access module. It will
withstand any CV in the range -12V...+12V and the bus access module cannot
generate a voltage beyond these values. If you cannot find the fault please
follow the repair notes on the FAQ page of our website:

www.doepfer.com > English > FAQ > General > Repair procedure

Best wishes
Dieter Doepfer

> -----Ursprüngliche Nachricht-----
> Von: xxxxxxx_xxxx@xxxxxxxxxxx.xxx [mailto:xxxxxxx_xxxx@xxxxxxxxxxx.xxx]
> Gesendet: Montag, 26. September 2016 09:31
> An: xxxxxxx_xxxx@xxxxxxxxxxx.xxx
> Betreff: [Doepfer_a100] a111( high end vco with 3340) issue
>
>
>
>
>
> hi friends
>
> Yesterday my dear A111 stopped to work..., perhaps (i m not
> totally sure) it was damaged by a wrong voltaje supplied by my
> doepfer bus-Access  module, which had a intermitent failure due
> to a defective bus ribbon cable..( i know i don t need to use the
> cv input because my bus board has the jumpers inside!)
>
> Where should I check ? Maybe CEM is dead?
>
> Maaaany thanks to everyone!!
>
> Kind regards from Spain
>
> Miguel



------------------------------------

------------------------------------


------------------------------------

Yahoo Groups Links

<*> To visit your group on the web, go to:
    http://groups.yahoo.com/group/Doepfer_a100/

<*> Your email settings:
    Individual Email | Traditional

<*> To change settings online go to:
    http://groups.yahoo.com/group/Doepfer_a100/join
    (Yahoo! ID required)

<*> To change settings via email:
    xxxxxxx_xxxx-xxxxxx@xxxxxxxxxxx.xxx 
    xxxxxxx_xxxx-xxxxxxxxxxxx@xxxxxxxxxxx.xxx

<*> To unsubscribe from this group, send an email to:
    xxxxxxx_xxxx-xxxxxxxxxxx@xxxxxxxxxxx.xxx

<*> Your use of Yahoo Groups is subject to:
    https://info.yahoo.com/legal/us/yahoo/utos/terms/