From yahoo Sent Fri, Jan 24th 2014, 14:48
I'm sorry - that's not possible because in this case both A-155 share the
same address signals (no matter if the A-154 is active or the address
generation unit of the first A-155 is used). You need a separate A-154 for
each A-155 or you may run the second A-155 stand-alone without A-154.
Best wishes
Dieter Doepfer
> Hi All,
>
> I have 2 x A155s connected to an A154. When you disable the
> A154 Master On/Off switch is there any way of getting each of the
> A155s to run from their individual trigger inputs? When I input
> a trigger into the step input of the 1st A155 both units still
> progress on the same trigger. It would be useful to have the
> second A155 running at sub-divisions of the master clock with its
> own reset point for poly-rhythms/Steve Reich piano phase style
> sequencing etc.
>
> Cheers,
>
> Gavin.
------------------------------------