AW: [Doepfer_a100] A147-2 VCDLFO question

From yahoo
Sent Wed, Jan 2nd 2019, 13:18

Hello,

please make sure that the output level of the Gate/Clock/Reset/Start/Stop
outputs is set to +12V (not +5V).
And make sure that the frequency of the A-147-2 is not too low. The
frequency of the A-147-2 should be not much less than the clock signal
coming from the Dark Time. Otherwise the period of the A-147-2 is to low to
generate a noticeable signal before the next reset appears.

Best wishes
Dieter Doepfer


> -----Ursprüngliche Nachricht-----
> Von: xxxxxxx_xxxx@xxxxxxxxxxx.xxx [mailto:xxxxxxx_xxxx@xxxxxxxxxxx.xxx]
> Gesendet: Dienstag, 25. Dezember 2018 19:52
> An: xxxxxxx_xxxx@xxxxxxxxxxx.xxx
> Betreff: [Doepfer_a100] A147-2 VCDLFO question
>
>
> Hello and happy christmas to everyone,
>
> I am using an external clock e.g from dark time to sync/reset the A147-2,
> as soon as I am increasing the frequency knob of the lfo, the
> outputs are in perfect
> sync with the external clock. As soon as I am decreasing the
> frequency knob I have no
> output signal from the lfo, the leds are not blinking. Is it a
> normal behaviour?
>
>
> Best regards,
> Miltos



------------------------------------

------------------------------------


------------------------------------

Yahoo Groups Links

<*> To visit your group on the web, go to:
    http://groups.yahoo.com/group/Doepfer_a100/

<*> Your email settings:
    Individual Email | Traditional

<*> To change settings online go to:
    http://groups.yahoo.com/group/Doepfer_a100/join
    (Yahoo! ID required)

<*> To change settings via email:
    xxxxxxx_xxxx-xxxxxx@xxxxxxxxxxx.xxx 
    xxxxxxx_xxxx-xxxxxxxxxxxx@xxxxxxxxxxx.xxx

<*> To unsubscribe from this group, send an email to:
    xxxxxxx_xxxx-xxxxxxxxxxx@xxxxxxxxxxx.xxx

<*> Your use of Yahoo Groups is subject to:
    https://info.yahoo.com/legal/us/yahoo/utos/terms/